Microbiological Quality of Laboratories Works Stations: Impact of a System of Saturated Dry Spray Steam

H. Ahouandjnou

Laboratoire National de Contrôle de Qualité des Médicaments et Consommables Médicaux (LNCQ), Ministère de la Santé, 06 BP 139 Cotonou, Benin and Laboratoire de Microbiologie et de Technologie Alimentaire, Faculté des Sciences et Techniques, Université d’Abomey-Calavi, ISBA-Champ de foire, 01 BP 526 Cotonou, Benin

F. Baba-Moussa

Laboratoire National de Contrôle de Qualité des Médicaments et Consommables Médicaux (LNCQ), Ministère de la Santé, 06 BP 139 Cotonou, Benin and Laboratoire de Microbiologie et de Technologie Alimentaire, Faculté des Sciences et Techniques, Université d’Abomey-Calavi, ISBA-Champ de foire, 01 BP 526 Cotonou, Benin

V. Dougnon

Laboratoire de Recherche en Biologie Appliquée (LARBA), Ecole Polytechnique d’Abomey-Calavi (EPAC), Université d’Abomey-Calavi, 01 BP 2009 Cotonou, Benin

J. Bonou

Laboratoire National de Contrôle de Qualité des Médicaments et Consommables Médicaux (LNCQ), Ministère de la Santé, 06 BP 139 Cotonou, Benin and Laboratoire de Microbiologie et de Technologie Alimentaire, Faculté des Sciences et Techniques, Université d’Abomey-Calavi, ISBA-Champ de foire, 01 BP 526 Cotonou, Benin

Z. Adeoti

Laboratoire de Microbiologie et de Technologie Alimentaire, Faculté des Sciences et Techniques, Université d’Abomey-Calavi, ISBA-Champ de foire, 01 BP 526 Cotonou, Benin

F. Toukourou

Laboratoire de Microbiologie et de Technologie Alimentaire, Faculté des Sciences et Techniques, Université d’Abomey-Calavi, ISBA-Champ de foire, 01 BP 526 Cotonou, Benin

L. Baba-Moussa *

Laboratoire de Biologie et de Typage Moléculaire en Microbiologie, Faculté des Sciences et Techniques, Université d’Abomey-Calavi, 05 BP 1604 Cotonou, Benin

*Author to whom correspondence should be addressed.


Abstract

Hygiene and sanitation in laboratories are some important focus for the well-being of scientists and workers. Due to the lack of these notions, a new sanitation system named Polti Sani System has been tested to overcome the limitations of traditional methods.

For this work, some American Type Culture Collection and Institute Pasteur of Strasbourg reference strains have been used. The biocides activities of the Sani System were assessed by the count of the total aerobic mesophilic bacteria in the working environment before and after disinfection. The Adenosine Triphosphate was also quantified. After a time contact of 30 seconds, Sani System reduced more than five logarithmic levels, the bacterial rate tested. The log reduction achieved with the fungi in the same conditions were greater than four logarithmic levels. The antimicrobial activity was observed both in the environment and on inert supports made of glasses, Plexiglas or tiles with an average reduction rate of 99.13%. This study showed that the Sani System associated with ATP-metry can be successfully used to quickly check the hygiene standards on surfaces or lab environment. It is a real challenge in terms of quality, efficiency and safety for the laboratories.

Keywords: Laboratory safety, sanitation system, saturated steam


How to Cite

Ahouandjnou, H., F. Baba-Moussa, V. Dougnon, J. Bonou, Z. Adeoti, F. Toukourou, and L. Baba-Moussa. 2015. “Microbiological Quality of Laboratories Works Stations: Impact of a System of Saturated Dry Spray Steam”. Microbiology Research Journal International 11 (1):1-8. https://doi.org/10.9734/BMRJ/2016/20228.